Imaging
AF
Related files:
-
🔬 Background doc: More details about this type.
- 📝 Excel template: For metadata entry.
- 📝 TSV template: Alternative for metadata entry.
This schema is for autofluorescence (AF). For an example of an AF dataset & directory, see this example autofluorescence dataset and click the Globus link.
Metadata schema
Version 1 (use this one)
Shared by all types
version
Version of the schema to use when validating this metadata.
constraint | value |
---|---|
enum | 1 |
required | True |
description
Free-text description of this assay.
constraint | value |
---|---|
required | True |
donor_id
HuBMAP Display ID of the donor of the assayed tissue. Example: ABC123
.
constraint | value |
---|---|
pattern (regular expression) | [A-Z]+[0-9]+ |
required | True |
tissue_id
HuBMAP Display ID of the assayed tissue. Example: ABC123-BL-1-2-3_456
.
constraint | value |
---|---|
pattern (regular expression) | (([A-Z]+[0-9]+)-[A-Z]{2}\d*(-\d+)+(_\d+)?)(,([A-Z]+[0-9]+)-[A-Z]{2}\d*(-\d+)+(_\d+)?)* |
required | True |
execution_datetime
Start date and time of assay, typically a date-time stamped folder generated by the acquisition instrument. YYYY-MM-DD hh:mm, where YYYY is the year, MM is the month with leading 0s, and DD is the day with leading 0s, hh is the hour with leading zeros, mm are the minutes with leading zeros.
constraint | value |
---|---|
type | datetime |
format | %Y-%m-%d %H:%M |
required | True |
protocols_io_doi
DOI for protocols.io referring to the protocol for this assay.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
operator
Name of the person responsible for executing the assay.
constraint | value |
---|---|
required | True |
operator_email
Email address for the operator.
constraint | value |
---|---|
format | email |
required | True |
pi
Name of the principal investigator responsible for the data.
constraint | value |
---|---|
required | True |
pi_email
Email address for the principal investigator.
constraint | value |
---|---|
format | email |
required | True |
assay_category
Each assay is placed into one of the following 4 general categories: generation of images of microscopic entities, identification & quantitation of molecules by mass spectrometry, imaging mass spectrometry, and determination of nucleotide sequence.
constraint | value |
---|---|
enum | imaging |
required | True |
assay_type
The specific type of assay being executed.
constraint | value |
---|---|
enum | AF |
required | True |
analyte_class
Analytes are the target molecules being measured with the assay. Leave blank if not applicable.
constraint | value |
---|---|
required | False |
is_targeted
Specifies whether or not a specific molecule(s) is/are targeted for detection/measurement by the assay.
constraint | value |
---|---|
type | boolean |
required | True |
acquisition_instrument_vendor
An acquisition instrument is the device that contains the signal detection hardware and signal processing software. Assays generate signals such as light of various intensities or color or signals representing the molecular mass.
constraint | value |
---|---|
required | True |
acquisition_instrument_model
Manufacturers of an acquisition instrument may offer various versions (models) of that instrument with different features or sensitivities. Differences in features or sensitivities may be relevant to processing or interpretation of the data.
constraint | value |
---|---|
required | True |
Unique to this type
resolution_x_value
The width of a pixel.
constraint | value |
---|---|
type | number |
required | True |
resolution_x_unit
The unit of measurement of the width of a pixel. Leave blank if not applicable.
constraint | value |
---|---|
enum | nm or um |
required | False |
required if | resolution_x_value present |
resolution_y_value
The height of a pixel.
constraint | value |
---|---|
type | number |
required | True |
resolution_y_unit
The unit of measurement of the height of a pixel. Leave blank if not applicable.
constraint | value |
---|---|
enum | nm or um |
required | False |
required if | resolution_y_value present |
resolution_z_value
Optional if assay does not have multiple z-levels. Note that this is resolution within a given sample: z-pitch (resolution_z_value) is the increment distance between image slices, ie. the microscope stage is moved up or down in increments to capture images of several focal planes.
constraint | value |
---|---|
type | number |
required | True |
resolution_z_unit
The unit of incremental distance between image slices. Leave blank if not applicable.
constraint | value |
---|---|
enum | mm , um , or nm |
required | False |
required if | resolution_z_value present |
number_of_channels
Number of channels capturing the emission spectrum from natural fluorophores in the sample.
constraint | value |
---|---|
type | integer |
required | True |
overall_protocols_io_doi
DOI for protocols.io referring to the overall protocol for the assay.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
contributors_path
Relative path to file with ORCID IDs for contributors for this dataset.
constraint | value |
---|---|
required | True |
data_path
Relative path to file or directory with instrument data. Downstream processing will depend on filename extension conventions.
constraint | value |
---|---|
required | True |
Version 0
Shared by all types
donor_id
HuBMAP Display ID of the donor of the assayed tissue. Example: ABC123
.
constraint | value |
---|---|
pattern (regular expression) | [A-Z]+[0-9]+ |
required | True |
tissue_id
HuBMAP Display ID of the assayed tissue. Example: ABC123-BL-1-2-3_456
.
constraint | value |
---|---|
pattern (regular expression) | ([A-Z]+[0-9]+)-[A-Z]{2}\d*(-\d+)+(_\d+)? |
required | True |
execution_datetime
Start date and time of assay, typically a date-time stamped folder generated by the acquisition instrument. YYYY-MM-DD hh:mm, where YYYY is the year, MM is the month with leading 0s, and DD is the day with leading 0s, hh is the hour with leading zeros, mm are the minutes with leading zeros.
constraint | value |
---|---|
type | datetime |
format | %Y-%m-%d %H:%M |
required | True |
protocols_io_doi
DOI for protocols.io referring to the protocol for this assay.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
operator
Name of the person responsible for executing the assay.
constraint | value |
---|---|
required | True |
operator_email
Email address for the operator.
constraint | value |
---|---|
format | email |
required | True |
pi
Name of the principal investigator responsible for the data.
constraint | value |
---|---|
required | True |
pi_email
Email address for the principal investigator.
constraint | value |
---|---|
format | email |
required | True |
assay_category
Each assay is placed into one of the following 4 general categories: generation of images of microscopic entities, identification & quantitation of molecules by mass spectrometry, imaging mass spectrometry, and determination of nucleotide sequence.
constraint | value |
---|---|
enum | imaging |
required | True |
assay_type
The specific type of assay being executed.
constraint | value |
---|---|
enum | AF |
required | True |
analyte_class
Analytes are the target molecules being measured with the assay. Leave blank if not applicable.
constraint | value |
---|---|
required | False |
is_targeted
Specifies whether or not a specific molecule(s) is/are targeted for detection/measurement by the assay.
constraint | value |
---|---|
type | boolean |
required | True |
acquisition_instrument_vendor
An acquisition instrument is the device that contains the signal detection hardware and signal processing software. Assays generate signals such as light of various intensities or color or signals representing the molecular mass.
constraint | value |
---|---|
required | True |
acquisition_instrument_model
Manufacturers of an acquisition instrument may offer various versions (models) of that instrument with different features or sensitivities. Differences in features or sensitivities may be relevant to processing or interpretation of the data.
constraint | value |
---|---|
required | True |
Unique to this type
resolution_x_value
The width of a pixel.
constraint | value |
---|---|
type | number |
required | True |
resolution_x_unit
The unit of measurement of the width of a pixel. Leave blank if not applicable.
constraint | value |
---|---|
enum | nm or um |
required | False |
required if | resolution_x_value present |
resolution_y_value
The height of a pixel.
constraint | value |
---|---|
type | number |
required | True |
resolution_y_unit
The unit of measurement of the height of a pixel. Leave blank if not applicable.
constraint | value |
---|---|
enum | nm or um |
required | False |
required if | resolution_y_value present |
resolution_z_value
Optional if assay does not have multiple z-levels. Note that this is resolution within a given sample: z-pitch (resolution_z_value) is the increment distance between image slices, ie. the microscope stage is moved up or down in increments to capture images of several focal planes.
constraint | value |
---|---|
type | number |
required | True |
resolution_z_unit
The unit of incremental distance between image slices. Leave blank if not applicable.
constraint | value |
---|---|
enum | mm , um , or nm |
required | False |
required if | resolution_z_value present |
number_of_channels
Number of channels capturing the emission spectrum from natural fluorophores in the sample.
constraint | value |
---|---|
type | integer |
required | True |
overall_protocols_io_doi
DOI for protocols.io referring to the overall protocol for the assay.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
contributors_path
Relative path to file with ORCID IDs for contributors for this dataset.
constraint | value |
---|---|
required | True |
data_path
Relative path to file or directory with instrument data. Downstream processing will depend on filename extension conventions.
constraint | value |
---|---|
required | True |
Directory schemas
pattern | required? | description |
---|---|---|
(processedMicroscopy|processed_microscopy)/[^/]+_images/[^/]+\.ome\.(tif|tiff) |
✓ | OME TIFF files (multichannel, multi-layered, image pyramids) produced by the autofluorescence microscopy |
(processedMicroscopy|processed_microscopy)/[^/]+_transformations/[^/]+\.txt |
Transformations to IMS (related) data | |
(rawMicroscopy|raw_microscopy)/[^/]+\.xml |
✓ | XML metadata file from the autofluorescence microscopy experiments |
(rawMicroscopy|raw_microscopy)/[^/]+\.czi |
✓ | Raw microscope file for the experiment |
extras\/.* |
Folder for general lab-specific files related to the dataset. [Exists in all assays] |