Sequence Assays
WGS
Related files:
-
🔬 Background doc: More details about this type.
- 📝 Excel template: For metadata entry.
- 📝 TSV template: Alternative for metadata entry.
Metadata schema
Version 1 (use this one)
Shared by all types
version
description
donor_id
tissue_id
execution_datetime
protocols_io_doi
operator
operator_email
pi
pi_email
assay_category
assay_type
analyte_class
is_targeted
acquisition_instrument_vendor
acquisition_instrument_model
Unique to this type
gdna_fragmentation_quality_assurance
dna_assay_input_value
dna_assay_input_unit
library_construction_method
library_construction_protocols_io_doi
library_layout
library_adapter_sequence
library_final_yield
library_final_yield_unit
library_average_fragment_size
sequencing_reagent_kit
sequencing_read_format
sequencing_read_percent_q30
sequencing_phix_percent
contributors_path
data_path
Shared by all types
version
Version of the schema to use when validating this metadata.
constraint | value |
---|---|
enum | 1 |
required | True |
description
Free-text description of this assay.
constraint | value |
---|---|
required | True |
donor_id
HuBMAP Display ID of the donor of the assayed tissue. Example: ABC123
.
constraint | value |
---|---|
pattern (regular expression) | [A-Z]+[0-9]+ |
required | True |
tissue_id
HuBMAP Display ID of the assayed tissue. Example: ABC123-BL-1-2-3_456
.
constraint | value |
---|---|
pattern (regular expression) | (([A-Z]+[0-9]+)-[A-Z]{2}\d*(-\d+)+(_\d+)?)(,([A-Z]+[0-9]+)-[A-Z]{2}\d*(-\d+)+(_\d+)?)* |
required | True |
execution_datetime
Start date and time of assay, typically a date-time stamped folder generated by the acquisition instrument. YYYY-MM-DD hh:mm, where YYYY is the year, MM is the month with leading 0s, and DD is the day with leading 0s, hh is the hour with leading zeros, mm are the minutes with leading zeros.
constraint | value |
---|---|
type | datetime |
format | %Y-%m-%d %H:%M |
required | True |
protocols_io_doi
DOI for protocols.io referring to the protocol for this assay.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
operator
Name of the person responsible for executing the assay.
constraint | value |
---|---|
required | True |
operator_email
Email address for the operator.
constraint | value |
---|---|
format | email |
required | True |
pi
Name of the principal investigator responsible for the data.
constraint | value |
---|---|
required | True |
pi_email
Email address for the principal investigator.
constraint | value |
---|---|
format | email |
required | True |
assay_category
Each assay is placed into one of the following 4 general categories: generation of images of microscopic entities, identification & quantitation of molecules by mass spectrometry, imaging mass spectrometry, and determination of nucleotide sequence.
constraint | value |
---|---|
enum | sequence |
required | True |
assay_type
The specific type of assay being executed.
constraint | value |
---|---|
enum | WGS |
required | True |
analyte_class
Analytes are the target molecules being measured with the assay.
constraint | value |
---|---|
enum | DNA |
required | True |
is_targeted
Specifies whether or not a specific molecule(s) is/are targeted for detection/measurement by the assay.
constraint | value |
---|---|
type | boolean |
required | True |
acquisition_instrument_vendor
An acquisition instrument is the device that contains the signal detection hardware and signal processing software. Assays generate signals such as light of various intensities or color or signals representing the molecular mass.
constraint | value |
---|---|
required | True |
acquisition_instrument_model
Manufacturers of an acquisition instrument may offer various versions (models) of that instrument with different features or sensitivities. Differences in features or sensitivities may be relevant to processing or interpretation of the data.
constraint | value |
---|---|
required | True |
Unique to this type
gdna_fragmentation_quality_assurance
Is the gDNA integrity good enough for WGS? This is usually checked through running a gel.
constraint | value |
---|---|
enum | Pass or Fail |
required | True |
dna_assay_input_value
Amount of DNA input into library preparation.
constraint | value |
---|---|
type | number |
required | True |
dna_assay_input_unit
Units of DNA input into library preparation. Leave blank if not applicable.
constraint | value |
---|---|
enum | ug |
required | False |
required if | dna_assay_input_value present |
library_construction_method
Describes DNA library preparation kit. Modality of isolating gDNA, Fragmentation and generating sequencing libraries.
constraint | value |
---|---|
required | True |
library_construction_protocols_io_doi
A link to the protocol document containing the library construction method (including version) that was used.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
library_layout
State whether the library was generated for single-end or paired end sequencing.
constraint | value |
---|---|
enum | single-end or paired-end |
required | True |
library_adapter_sequence
The adapter sequence to be used for adapter trimming starting with the 5’ end. (eg. 5-ATCCTGAGAA) Example: 5-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATCT
.
constraint | value |
---|---|
pattern (regular expression) | 5-[GATCU]+ |
required | True |
library_final_yield
Total amount of library after final pcr amplification step.
constraint | value |
---|---|
type | number |
required | True |
library_final_yield_unit
Total units of library after final pcr amplification step. Leave blank if not applicable.
constraint | value |
---|---|
enum | ng |
required | False |
required if | library_final_yield present |
library_average_fragment_size
Average size in basepairs (bp) of sequencing library fragments estimated via gel electrophoresis or bioanalyzer/tapestation.
constraint | value |
---|---|
type | integer |
required | True |
sequencing_reagent_kit
Reagent kit used for sequencing.
constraint | value |
---|---|
required | True |
sequencing_read_format
Slash-delimited list of the number of sequencing cycles for, for example, Read1, i7 index, i5 index, and Read2. Example: 12/34/56
.
constraint | value |
---|---|
pattern (regular expression) | \d+(/\d+)+ |
required | True |
sequencing_read_percent_q30
Q30 is the weighted average of all the reads (e.g. # bases UMI * q30 UMI + # bases R2 * q30 R2 + …)
constraint | value |
---|---|
type | number |
required | True |
minimum | 0 |
maximum | 100 |
sequencing_phix_percent
Percent PhiX loaded to the run.
constraint | value |
---|---|
type | number |
required | True |
minimum | 0 |
maximum | 100 |
contributors_path
Relative path to file with ORCID IDs for contributors for this dataset.
constraint | value |
---|---|
required | True |
data_path
Relative path to file or directory with instrument data. Downstream processing will depend on filename extension conventions.
constraint | value |
---|---|
required | True |
Version 0
Shared by all types
donor_id
HuBMAP Display ID of the donor of the assayed tissue. Example: ABC123
.
constraint | value |
---|---|
pattern (regular expression) | [A-Z]+[0-9]+ |
required | True |
tissue_id
HuBMAP Display ID of the assayed tissue. Example: ABC123-BL-1-2-3_456
.
constraint | value |
---|---|
pattern (regular expression) | ([A-Z]+[0-9]+)-[A-Z]{2}\d*(-\d+)+(_\d+)? |
required | True |
execution_datetime
Start date and time of assay, typically a date-time stamped folder generated by the acquisition instrument. YYYY-MM-DD hh:mm, where YYYY is the year, MM is the month with leading 0s, and DD is the day with leading 0s, hh is the hour with leading zeros, mm are the minutes with leading zeros.
constraint | value |
---|---|
type | datetime |
format | %Y-%m-%d %H:%M |
required | True |
protocols_io_doi
DOI for protocols.io referring to the protocol for this assay.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
operator
Name of the person responsible for executing the assay.
constraint | value |
---|---|
required | True |
operator_email
Email address for the operator.
constraint | value |
---|---|
format | email |
required | True |
pi
Name of the principal investigator responsible for the data.
constraint | value |
---|---|
required | True |
pi_email
Email address for the principal investigator.
constraint | value |
---|---|
format | email |
required | True |
assay_category
Each assay is placed into one of the following 4 general categories: generation of images of microscopic entities, identification & quantitation of molecules by mass spectrometry, imaging mass spectrometry, and determination of nucleotide sequence.
constraint | value |
---|---|
enum | sequence |
required | True |
assay_type
The specific type of assay being executed.
constraint | value |
---|---|
enum | WGS |
required | True |
analyte_class
Analytes are the target molecules being measured with the assay.
constraint | value |
---|---|
enum | DNA |
required | True |
is_targeted
Specifies whether or not a specific molecule(s) is/are targeted for detection/measurement by the assay.
constraint | value |
---|---|
type | boolean |
required | True |
acquisition_instrument_vendor
An acquisition instrument is the device that contains the signal detection hardware and signal processing software. Assays generate signals such as light of various intensities or color or signals representing the molecular mass.
constraint | value |
---|---|
required | True |
acquisition_instrument_model
Manufacturers of an acquisition instrument may offer various versions (models) of that instrument with different features or sensitivities. Differences in features or sensitivities may be relevant to processing or interpretation of the data.
constraint | value |
---|---|
required | True |
Unique to this type
gdna_fragmentation_quality_assurance
Is the gDNA integrity good enough for WGS? This is usually checked through running a gel.
constraint | value |
---|---|
enum | Pass or Fail |
required | True |
dna_assay_input_value
Amount of DNA input into library preparation.
constraint | value |
---|---|
type | number |
required | True |
dna_assay_input_unit
Units of DNA input into library preparation. Leave blank if not applicable.
constraint | value |
---|---|
enum | ug |
required | False |
required if | dna_assay_input_value present |
library_construction_method
Describes DNA library preparation kit. Modality of isolating gDNA, Fragmentation and generating sequencing libraries.
constraint | value |
---|---|
required | True |
library_construction_protocols_io_doi
A link to the protocol document containing the library construction method (including version) that was used.
constraint | value |
---|---|
required | True |
pattern (regular expression) | 10\.17504/.* |
url | prefix: https://dx.doi.org/ |
library_layout
State whether the library was generated for single-end or paired end sequencing.
constraint | value |
---|---|
enum | single-end or paired-end |
required | True |
library_adapter_sequence
The adapter sequence to be used for adapter trimming starting with the 5’ end. (eg. 5-ATCCTGAGAA) Example: 5-AATGATACGGCGACCACCGAGATCTACACTCTTTCCCTACACGACGCTCTTCCGATCT
.
constraint | value |
---|---|
pattern (regular expression) | 5-[GATCU]+ |
required | True |
library_final_yield
Total amount of library after final pcr amplification step.
constraint | value |
---|---|
type | number |
required | True |
library_final_yield_unit
Total units of library after final pcr amplification step. Leave blank if not applicable.
constraint | value |
---|---|
enum | ng |
required | False |
required if | library_final_yield present |
library_average_fragment_size
Average size in basepairs (bp) of sequencing library fragments estimated via gel electrophoresis or bioanalyzer/tapestation.
constraint | value |
---|---|
type | integer |
required | True |
sequencing_reagent_kit
Reagent kit used for sequencing.
constraint | value |
---|---|
required | True |
sequencing_read_format
Slash-delimited list of the number of sequencing cycles for, for example, Read1, i7 index, i5 index, and Read2. Example: 12/34/56
.
constraint | value |
---|---|
pattern (regular expression) | \d+(/\d+)+ |
required | True |
sequencing_read_percent_q30
Q30 is the weighted average of all the reads (e.g. # bases UMI * q30 UMI + # bases R2 * q30 R2 + …)
constraint | value |
---|---|
type | number |
required | True |
minimum | 0 |
maximum | 100 |
sequencing_phix_percent
Percent PhiX loaded to the run.
constraint | value |
---|---|
type | number |
required | True |
minimum | 0 |
maximum | 100 |
contributors_path
Relative path to file with ORCID IDs for contributors for this dataset.
constraint | value |
---|---|
required | True |
data_path
Relative path to file or directory with instrument data. Downstream processing will depend on filename extension conventions.
constraint | value |
---|---|
required | True |
Directory schemas
pattern | required? | description |
---|---|---|
[^/]+\.fastq\.gz |
✓ | Compressed FastQ file |
extras\/.* |
Folder for general lab-specific files related to the dataset. [Exists in all assays] |